Natural Gas Generator Set Installation Manual-GF Series
Doc. 17855, Rel. 03/2014
3-9
3.8.4 3-Way Catalyst Installation
WARNING
To reduce the possibility of personal injury, use a
hoist or get assistance to lift the assembly.
CAUTION
The existing exhaust pipe silencer hangers can
not hold the weight of a natural gas catalyst.
Install appropriate customer supplied natural gas
3-way catalyst mounting brackets.
1. Bolt the natural gas 3-way catalyst mounting
bracket (supplied by the customer according to
the application), to a solid structure.
2. Install the customer supplied mounting clamps to
the natural gas 3-way catalyst housing. Tighten
the mounting clamps enough to hold them in
place (per Figure 3-4 and Figure 3-5) and to
allow movement to connect the inlet and outlet
exhaust pipes.
3. Connect the inlet and outlet exhaust pipes to the
catalyst inlet and outlet.
4. Connect the customer supplied mounting
clamps to the catalyst mounting bracket.
5. Tighten the natural gas catalyst mounting
clamps.
1. Hangers
2. Fixed Support
3. Expansion Joint (optional)
4. 3-Way Catalyst
5. Silencer
6. Expansion Joint
7. Pre O2 and Temp Sensor Port (180° offset)
8. Post O2 and Temp Sensor Port
9. Engine
Figure 3-5 Recommended Vertical Mounting Configuration (Typical)