Crankshaft Adapter - Cleaning and
Inspection (01-11)
Cleaning
Warning: When performing the following procedures,
wear eye protection. Also, the wire brush must be rated
for the RPM being used if the brush is motor driven.
Use an emery cloth or a steel wire brush. Clean the inside
and the outside diameters of the adapter.
Use solvent to clean the adapter. Dry with compressed air.
Inspection
Visually inspect the adapter for cracks.
Measure the inside pilot diameter.
Inside Pilot Diameter
mm in
92.10 MIN 3.626
92.17 MAX 3.629